1M2 Commands ListIndex Introduction 2Input list 2Output list 4Using the commands 5 SVx
10STISet time Command: STI Arguments: time (hhmmss, only in 24h format)Example: Set time to 13h45m10s Command #|M001|F001|STI|134510|09f2|return
11SMXXSet mute state in a zone Command: SMXX Arguments: 0 (disable) or 1 (enable)Example: Enable mute in zone 1 Command #|M001|F001|SM1|1|179c|ret
12GLGet’s the system load in %. The load increases when you add generators, mixing, bass, treble …. the M2 will respond with ‘L’ in the argument of th
13DEFAll zone settings and device settings will be reset to factory default. (except for the network settings) Command: DEF Arguments: 0 (none)Examp
14WOWConnected Wall Panels. Request a response from all Wall Panel devices that are connected to the M2. Command: WOW Arguments: 0 (none)Example: Re
15PGPage command starts the page that is requested with the PGRQ command. Command: PG Arguments: X -> 0 = stop paging / 1 = start pagingExample o
16SLINESet line 9 (line 1 to 4 can be set to line 9) Command: SLINE Arguments: Line 1 to 4Example: set a line to line 9 (line 1 to 4 can be set) C
17SROFFSwitch relay off Command: SROFF Arguments: 00000000 (32 bit hex value)Example : turn off relay 1 and 2 Command #|M001|F001|SROFF|00000003|9
2PG Page 15 GIN Get Input Names 15 GZN Get Zone Names 15 SLINE Set Line 1 to 4 (For input 9)
3Fiber inputs 25 FB1 input 26 FB2 input 27 FB3 input 28 FB4 input 29 FB5 input 30 FB6 input 31 FB7 input 32 FB8 input Scenes When a scene is s
4Output list Direct outputs 1 Output 1 2 Output 2 3 Output 3 4 Output 4 5 Output 5 6 Output 6 7 Output 7 8 Output 8Wall panel outputs 12 WP1
5Using the commands The M2 has various control ports which are all accepting the same commands. - RS-232 port - All RS-485 ports (Peripheral input
6Commands listSVxx Set volume for an output to a certain level Command: SVxx, where xx is the output number Arguments: Volume in neg dB -> 0 is m
7GVXXGet volume in a zone Command: GVXX, where XX is the zone number Arguments: 0 (none)Example: Get volume in zone 3 Command #|M001|F001|GV3|0|29
8SRDXXSet Routing down Command: SRDXX, where XX is the zone number. This command scrolls true the 8 inputs defined for that zone. Arguments: 0 (non
9SBXXSet bass in a zone Command: SBXX Arguments: from -9dB to +9dBExample: Set bass in zone 5 to -3dB Command #|M001|F001|SB5|-3|4112|return Answ